Customization: | Available |
---|---|
Certification: | CE, FDA, ISO13485 |
Scale: | Large |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Specifications | |
1.Fluoroscopic Capacity | |
Max rated capacity | Tube Current 4mA, Tube Voltage 120kV |
Automatic Fluoroscopy | Tube Voltage:40kV~120kV Adjust Automatically |
Tube Current | 0.3mA~4mA Manually Settings |
Manual Fluoroscopy | Continuous Tube Voltage:40kV~120kV |
Continuous Tube Current | 0.3mA~4mA |
Pulse Fluoroscopy |
Continuous Tube Voltage 40kV~120kV |
Continuous Tube Current 4.1mA~8mA | |
2. Photography Capacity | |
Max rated capacity | 5 KW |
Tube Voltage and Current Combination |
40kV~49kV 1 ~180 mAs |
50kV~59kV 1 ~140 mAs | |
60kV~69kV 1 ~125 mAs | |
70kV~79kV 1 ~110 mAs | |
80kV~89kV 1 ~100 mAs | |
90kV~99kV 1 ~80 mAs | |
100kV~109kV 1 ~63 mAs | |
110kV~120kV 1 ~50 mA | |
Plate holder Size | 200mm×250mm(8″×10″)or 250mm×300mm(10″×12″) |
3. X-ray Tube | |
X-ray Tube Special for High Frequency | |
Fixed anode Dual-focus: large focus | 1.5, small focus: 0.3mm*0.3mm (Advantage) |
Inverter Frequency | 40KHz |
Thermal capacity | 35KJ (47KHU) |
4.Video System | |
Image Intensifier | Image Intensifier made by TOSHIBA (9″, 6″,4.5″) |
CCD Vidicon | Ultra low-light CCD camera imported from Japan |
Monitor | Horizontal 1000 lines and vertical 800 lines, Bandwidth : 12.5MHz, Image/sec : 75 |
CCU(central control) |
Recursive Filter: K=8,8 images storage, image upright, image overturn,positive & negative image;LIH(last Image Hold) and OSD(monitor display) |
5.Structure: | |
Directive wheel | ±90°revolution,can freely change the moving direction of the unit . Ascending & Descending Range of Pillar : ≥400mm |
C-arm | Forward and Backward Movement: 200mm Revolution around Horizontal Axis: ±180° |
Revolution around Vertical Axis | ±15°( Advantage), better than others' ±12.5°, easier to take special positions radiography ) |
Slip on orbit | 120°(+90°~ -30°) |
III Configuration | |
1.New (with electric auxiliary support arm) C-arm host | one set |
2.High-frequency high-voltage X-ray generator and high-frequency inverter power supply(5.0KW,40KHZ,120KV) | one set |
3.Toshiba 9-inch image intensifier | one set |
4. Imports of super-low-light digital camera | one set |
5.CCU in the high-definition progressive output control system | one set |
6.Dense grain grids | one set |
7.Electric adjustable speed limiter | one set |
8.19-inch HD monitor private medical | two set |
9.Single use hand-held controller | one set |
10. New TV Trolley | one set |
Category | Project | Content |
Fluoroscopic Capacity |
Photography Max rated capacity | 5.0KW |
Fluoroscopic ax rated capacity | Tube Current 4mA, Tube Voltage 120kV | |
Automatic Fluoroscopy | Tube Voltage:40kV~120kV adjust automatically Tube Current:0.3mA~4mA adjust automatically |
|
Manual Fluoroscopy | Tube Voltage:40kV~120kV Continuous Tube Current:0.3mA~4mA Continuous |
|
Pulse Fluoroscopy | Tube Voltage:40kV~120kV Continuous Tube Current:4.1mA~8mA Continuous |
|
Photography Tube Voltage and mA | 40 kV~120 kV 20-100mA | |
Plate holder Size | 200mm×250mm(8″×10″)or 250mm×300mm(10″×12″) |
|
X-ray Tube | X-ray Tube Special for High Frequency | Fixed anode Dual-focus, small focus: 0.3, Inverter Frequency: 40KHz |
Video System |
Image Intensifier | Image Intensifier made by TOSHIBA (9″) |
CCD Video camera | Ultra low-light CCD camera imported from Japan | |
Monitor | Horizontal 1000 lines and vertical 800 lines, Bandwidth : 12.5MHz, 50bit Image/sec : 25 |
|
CCU(central control) | Recursive Filter: K=8, 8 images storage, image upright, image overturn,positive & negative image;LIH(last image freeze, and OSD(monitor display) |
|
Structural performance | Directive wheel | ±90°revolution,can freely change the moving direction of the unit. |
Ascending & Descend | ≥400mm | |
C-arm | Forward and Backward Movement: 200mm Revolution around Horizontal Axis: ±180° Revolution around Vertical Axis : ±15° Focus screen distance:960mm C-arm opening: 760mm C-arm arc depth: 640mm Slip on orbit: 120°(+90°~ -30°) |