• in Stock Available Oxygen Ventilators
  • in Stock Available Oxygen Ventilators
  • in Stock Available Oxygen Ventilators
  • in Stock Available Oxygen Ventilators
  • in Stock Available Oxygen Ventilators

in Stock Available Oxygen Ventilators

Transport Package: Cartoon Box
Specification: 600X402X415mm
Origin: China
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
Crius V6
HS Code
9019200000
Production Capacity
500000 Piece/Year

Product Description

Crius V6 Ventilator Specifications
 
 
 
The ventilator is already integrated with expiratory volume monitor, pressure measurement device, and pressure release device. It is equipped with alarm system, O2 monitor, CO2 monitor and SpO2 monitor, where:
  1. The expiratory volume monitor, pressure measurement device, and pressure release device comply with ISO 80601-2-12 .
  2. The alarm system complies with IEC 60601-1-8.
  3. The O2 monitor complies with ISO 80601-2-55.
  4. The CO2 monitor complies with ISO 80601-2-55.
  5. The gas supply hose assembly complies with ISO 5359.
  6. The SpO2 monitor complies with ISO 80601-2-61.

Environmental Specifications

 
Main unit
Item Temperature (ºC) Relative humidity (non-condensing) Barometric pressure (kPa)

Operating

5 to 40
10 to 95 %
62 to 106*

Storage and transport
-20 to +60 (O2 sensor: -20 to +50) 10 to 95 %
50 to 106
The ventilator performance satisfies the specifications at barometric pressure 80 kPa to 106 kPa. The inspiration pressure of the ventilator can reach 60 cmH2O at barometric pressure 62 kPa to 80 kPa.
 

Safety Specifications

 
Type of protection against electric shock
Class I equipment with internal electrical power supply.
Degree of protection against electric shock
BF, defibrillation-proof
Operating mode Continuous
Degree of protection against hazards of explosion Ordinary equipment, without protection against explosion; not for use with flammable anaesthetics.


Degree of protection against harmful ingress of water
Degrees of protection provided by enclosures(IP Code)-IP21
Protection Index according the EN 60529 standard:
2: Protected against solid foreign objects of 12.5 mm diameter and greater
1: Protected against vertically falling water drops
Electrical connections between the equipment and the patient
Non-electrical connections
Equipment type Mobile
   

Power Requirements

 
External AC power supply
Input voltage 100 to 240 V
Input frequency 50/60 Hz
Input current 2.7 to 1.1A
Fuse T3.15 AH/250 V
External DC power supply
Input voltage 12 V
Input current 15A
Internal battery
Number of batteries One or two
Battery type Lithium-ion battery
Rated battery voltage 14.8 VDC
Battery capacity 5400 mAh for a single battery
Overcurrent protection 8.2 ± 5 %A

Time to shutdown
10± 5 % min at least (powered by new fully-charged batteries after the first low battery alarm)


Battery run time
180 min (powered by one new fully-charged battery in standard working condition);
360 min (powered by two new fully-charged batteries in standard working condition).
The standard work condition is:
      1. Ventilation mode : PC-ACV ;
      2. Pmax: 30cmH2O;
      3. Pinsp : 10 cmH2O;
      4. PEEP:5cmH2O
      5. Rate :10 bpm ;
 
      1. Tinsp : 2 s ;
      2. Tslope:1.0s;
      3. Trigger:0.5L/min;
      4. O2% : 21 Vol.% ;
      5. R: 20 cmH2O/L/s ;
      6. C: 20 ml/cmH2O ;
      7. Gas supply nominal work pressure : 400±100 kPa.
 

Physical Specifications

 
System noise

System noise
A-weighted sound pressure level (LpA) 45 dB(A) A-weighted sound power level (LWA53dB (A)
Main unit


Dimensions
1365 mm×526 mm×544 mm (height×width×depth) (including the
ventilator cart)
354 mm×315 mm×249 mm (height×width×depth) (excluding the ventilator cart)

Weight
Approximately 30 kg (including the ventilator cart) Approximately 10 kg (excluding the ventilator cart)
Caster
Caster 4 casters. All casters have brakes.
Display
Type TFT LCD
Size 15.6"
Resolution 1366 x 768 pixels
Brightness Adjustable
Touch screen Available, anti-glare.
LED indicator

Alarm LED
One (yellow and red. When high and medium priority alarms occur simultaneously, it flashes red only).
External power LED One (green; lit when the external power supply is connected).

Battery LED
One (green; lit when batteries are installed and external power supply is connected; flashing when powered by batteries; extinguished when no batteries are installed or external power supply is not connected.)

Operating status LED
One, namely, power switch key background light (green; lit when powered on and extinguished when powered off).

 
Audio indicator

Speaker
Gives off alarm tones and key tones; supports multi-level tone modulation. The alarm tones comply with the requirements of IEC60601-1-8.
Buzzer Gives off auxiliary audio alarm in case of speaker malfunction.
Connector

Network connector
A connector which supports connection with a PC to perform software upgrade and connection with external medical and information device.

RS-232 connector
Connects to the external calibration device for calibrating pressure. An external medical device can be connected via this connector to communicate with the ventilator.


USB connector
Exports captured screen, conducts ventilator software upgrade, configuration information export and history data (such as patient data, alarm log, calibration table) export, configuration transfer between machines of the same type via USB device.
Nurse call connector Connects to the hospital's nurse call system.

VGA connector
Outputs VGA video signals with the same contents to the primary display and connects to the external display (supporting display with resolution of 1366*768).

in Stock Available Oxygen Ventilators
in Stock Available Oxygen Ventilators
in Stock Available Oxygen Ventilators
in Stock Available Oxygen Ventilators
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now