The Smallest and exquisite handheld vital sign monitor in the world
Accurate measurement in 0.05% low perfusion index,the world leading production
in the movement environment
Provide the parameter of the PI(perfusion index 0.05%-20%)
Accurate measurement in all kind of extreme environment measurement such as neonatal and shock patients
NIBP adopt SAWAA(Self-Adaptive-Waveform-Amplitude-Adjust)algorithm and SAFD(Self-Adaptive-Fast-Deflation)algorithm
Easy operation by 3.5"color TFT screen and Up to 100users ID switch
Multiple vital signs measurement parameters for collocation optional
NIBP,SPO2,TEMP
SPO2,TEMP
NIBP,TEMP
Two measurements mode:Spot,Monitoring
Data storage capabilities,support for historical data view and trend chart back to see
In monitoring mode,can continuously record 48 hours of measurement data
In spot mode,100users ID,each user can store 200sets data
Support audio and visual alarm,support to set alarm uper and lower limit values
Lithium ion battery power supply
Optional charging dock
Performance Specifications
Display |
3.5'' color TFT |
Resolution |
320*480 |
Indicator |
Alarm Indicator, Power Indicator |
Trace |
1 plethysmogram waveform |
Alarm |
Probe off, low power |
Modes |
Visual and Audio |
Application |
Neonatal, Pediatric and adult patients |
NIBP
The wider NIBP measurement range
|
Adult |
PED |
NEO |
SYS |
40-270mmHg |
40-200mmHg |
40-135mmHg |
MEAN |
20-230mmHg |
20-165mmHg |
20-105mmHg |
DIA |
10-210mmHg |
10-150mmHg |
10-95mmHg |
Pulse Rate Range:40-240bpm
1.NIBP measurement accuracy:+-3mmHg
2.Pulse rate measurement accuracy:<=2%(>=100BPM) or 2 beats/min(<100BPM)
3.Independent software protection pressure
Adult:300mmHg PED:240mmHg NEO:150mmHg
4.Independent hardware protection pressure
Adult:320-330mmHg PED:265-275mmHg NEO:160-165mmHg
Oxygen Saturation (%SpO2)
1, Measurement range:
Measure range
SpO2: 0-100% PR: 0-254bpm
Perfusion Index: 0.05%-20%
Accuracy range:
SpO2 saturation: 70-100%
Pulse rate: 20-254BPM
Perfusion Index: 0.025%-20%
2 Measurement Accuracy
SpO2: Adult (including pediatric) + 2 digit (70-100%)
Not defined (<70%)
Neonate +3 digits not defined (<70%)
On motion condition + 3 digit
PR: Adult (including pediatric) + 3 digits
Neonate + d digits On motion condition + 3 digit
Perfusion Index: 0.05% - 20%
3, Resolution
SpO2 saturation: 1%
Pulse rate: 1BPM
Temperature
1, Measurement range: 25-45
ºC
2, Resolution: 0.1
ºC
3, Accuracy: 0.1
ºC
Power Type: Lithium ion battery
Operation time: 8 hours for normal operation
Temperature: Operating :0
ºC~ 45
ºC Starage/
Transportation: -20
ºC~65
ºC
Humidity: Operating 15% to 90% noncondensing
Storage: 0% to 95% noncondesing
Altitude: Operating Altitude: Up to 5000 meters
Size: Dimention 146mm*67mm*30mm
Weight: 250g
CO2
1, Measurement range:
ETCO2: 0-150MmHg (0-19.7%) (0-20kPa) RR: 3-150BPM
2, Accuracy range:
ETCO2 Range |
Accuracy |
0-40mmHg |
±2mmHg |
41-70mmHg |
±5% of reading |
71-100mmHg |
±8% of reading |
101-150mmHg |
± 10% of reading |
RR Accuracy: ±1BPM
2, Resolution:
ECTO2: 0.1mmHg RR: 1BPM
3, Setting compensation parameters
Pressure range: 450-850mmHg
Oxygen range: 0-100%
Equilibrium gas: N2O, He
4, Power Requirements: 5.0vdc ±5%, 1A(Module average power consumption is less than 1.3W)
5, Temperature: Work Environment: 10%-90% RH
Storage Environment: <90% RH